Full Text
Abstract
The purpose of the present investigation was to comparatively evaluate the performance characteristics of the test systems designed to verify the positive results of screening survey for HIV infection, such as the solid-phase immunoassay DS-EIA-HIV-AB/AG-SPECTR (Diagnosticheskiye Sistemy (Diagnostic Systems) Research-and-Production Association, Nizhni Novgorod) and tests based on immune blotting (IB). The investigation examined 15 seroconversion panels produced by ZeptoMetrix (USA) and BBI (USA). The use of the DS-EIA-HIV-AB/AG-SPECTR test system determined 88 of the 167 seroconversion panels as HIV positive. The IB-based tests revealed only 45 of the 167 samples as positive. Consequently, the application of the DS-EIA-HIV-AB/AG-SPECTR test system is more effective than the IB-based tests in early HIV infection.
Keywords
References
- Баранова Е. Н., Шарипова К. Н., Кудрявцева E. H. и др. Разработка и оценка нового теста для верификации исследований на маркеры ВИЧ-инфекции // Клин. лаб. диагн. - 2008. - № 3. - С. 40-41.
- Burke D. S., Brandt B. L., Redfield R. R. et al. Diagnosis of human immunodeficiency virus infection by immunoassay using a molecularly cloned and expressed virus envelope polypeptide. Comparison to Western blot on 2707 consecutive serum samples // Ann. Intern. Med. - 1987. - Vol. 106. N 5. - P. 671-676.
- Bush М. Р., Lee L. L. L., Satten G. A. Time course of detection of viral and serologic markers preceding human immunodeficiency virus type 1 seroconversion: implications for screening of blood and tissue donors // Transfusion. - 1995. - Vol. 35. - P. 91-97.
- Bush M. P., Kleinman S. H., Williams A. E. Frequency of human immunodeficiency virus (HIV) infection among contemporary Anti-HIV-1 and anti-HIV-1/2 supplemental test-indeterminate blood donors // Transfusion. - 1996. - Vol. 36. - P. 37-44.
- Carlson J. R., Bryant M. Д., Hinrichs S. H. et. al. AIDS serology testing in low-and high-risk groups // J. A. M. A. - 1985. - Vol. 259. - P. 2574-2579.
- Centers for disease control interpretation and use of the western blot assay for serodiagnosis of human immunodeficiency virus type 1 infection // Morbid. Mortal. Wkly. Rep. - 1989. - Vol. 38. - P. 1-7.
- Dobec M., Naegeli A., Furrer K., Kaeppeli F. Is Western blot alone sufficient to confirm a reactive result of a fourth-generation HIV screening assay? // Swiss. Med. Wkly. - 2006. - Vol. 136. - P. 672-673.
- Jackson J. B. Hanson M. R., Johnson G. M. Long-term follow up of blood donors with Indeterminate Human Immunodeficiency virus type 1 results on Western blot // Transfusion - 1995. - VoL. 35. - P. 98-102.
- Kline R. L., McNairn D., Holodilniy M. Evaluation of chiron HIV-l/HIV-2 recombinant immunoblot assay // J. Clin. Microbiol. - 1996. - Vol. 34. - P. 2650-2653.
- Lee J. H. Follow-up investigation of indeterminate Western blot results for antibody to human immunodeficiency virus type // J. Formos. Med. Assoc. - 1994. - Vol. 93. - P. 283-288.
- MacDonald K. L., Jakson J. B., Bowman R. J. et al. Performance characteristics of serological tests of human immunodeficiency virus type 1 (HIV-1) antibody among Minnesota blood donors // Ann. Intern. Med. - 1989. - Vol. 110. - P. 617-621.
- Mas A., Soriano V., Gutierrez М. et al. Reliability of a new recombinant immunoblot assay (RIBA HIV-1/HIV-2 SIA) as a supplemental (confirmatory) test for HIV-1 and HIV-2 infections // Transfus. Sci. - 1997. - Vol. 18, N 1. - P. 63-69.
- Meles H., Wolday D., Fontanet A. et al. Indeterminate human immunodeficiency virus Western blot profiles in Ethiopians with discordant screening assay results // Clin. Diagn. Lab. Immunol. - 2002. - Vol. 9. - P. 160-163.
- Pollet D. E., Saman E. L., Peeters D. C. et al. Confirmation and differentiation of antibodies to human immunodeficiency virus 1 and 2 with a strip-based assay including recombinant antigens and synthetic peptides // Clin. Chem.. - 1991. - Vol. 37, N 10. - P. 1700-1707.
- Ravanshad M., Sabahi F., Mahboudi F. et al. An accurate confirmation of human immunodeficiency virus type 1 (HIV-1) and 2 (HIV-2) infections with a dot blot assay using recombinant p24, gp41, gp120 and gp36 antigens // Int. J. Med. Sci. - 2004. - Vol. 1. - P. 193-200.
- Shwartz J. S., Dans P. E., Kinosian B. P. Human immunodeficiency virus test evaluation, performance, and use // J. A. M. A. - 1988. - Vol. 259. - P. 2574-2579.
- Rich J. D., Dickinson B. P., Spaulding A. et al. Interpretation of indeterminant HIV serology results in an incarcerated population // J. Acquire Immune Defic. Syndr. - 1998. - Vol. 17. - P. 376-379.
- Van Doornum G. J. J., Buimer M., Gobbers E. et al. Evaluation of an expanded Two-ELISA Approach for confirmation of reactive serum samples in an HIV-screening programme for pregnant women // J. Med. Virol. - 1998. - Vol. 54. - P. 285-290.
- Zaaijer H. L., van Rixel T., Kromosoeto J. N. R. et al. Validation of immunoblot assay (LiaTec HIV 3) for confirmaition of human immunodeficiency virus infection // Transfusion. - 1998. - Vol. 38. - P. 776-781.